Every answer cites notice numbers you can check on SAM.gov. See a real answer

Notices · Combined Synopsis/Solicitation

Research Triangle Park Forestry Sciences Laboratory HVAC Repair

Open. Responses are due in 4 days, on December 1, 2026, 5:00 PM ET.

Solicitation number1240BE27Q0025
Notice typeCombined Synopsis/Solicitation
AgencyAGRICULTURE, DEPARTMENT OF, FOREST SERVICE, SOUTHERN RESEARCH STATION
Set-asideSmall Business Set Aside - Total (SBA)
NAICS238220 Plumbing, Heating, and Air‑Conditioning Contractors
SBA size standard: $19M average annual receipts
Product or service codeJ041 Maint/Repair/Rebuild of Equipment- Refrigeration, Air Conditioning, and Air Circulating Equipment
Place of performanceDurham, NC 27713, USA
PostedNovember 19, 2026
Response dueDecember 1, 2026, 5:00 PM ET

Who holds the work now

Largest current award in NAICS 238220 at the Forest Service, by dollars obligated: CARVER CONSTRUCTION, LLC, current end date December 31, 2026. It may not be the contract this notice replaces.

Source: USAspending.gov, as of November 3, 2026.

Ask Claude about this notice

Add BidOpps AI to Claude, then type this:

Using BidOpps AI, read 1240BE27Q0025 in full and tell me what stage it's at.

Add to Claude

Your first 10 searches are free. No card.

From the attachments

Pulled by AI from the one file with text. Check the file before relying on a fact. A point with no row here was not found, which does not mean it doesn't apply. Each quote is the file's own words.

Evaluationhighest technically rated
C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf, page 7: "Once the highest technically rated offeror is identified, their price will be evaluated to determine whether it is fair and reasonable."
Evaluationbest value
C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf, page 7: "Award will be made to the offeror representing the best value to the Government."
Questions dueNovember 27, 2026, 17:00 PM EST
C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf, page 9: "Questions shall be submitted via email to Jared Machgan at jared.machgan@usda.gov no later than November 27, 2026, at 17:00 PM EST."
Past performanceDirect experience completed by your firm over the past three years
C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf, page 8: "Past Performance – Direct experience completed by your firm over the past three years. Include a brief description of the project"
Contract typefirm-fixed-price
C04-1 1240BE27Q0025 Schedule and Statement of Work.pdf, page 7: "It is anticipated that a firm fixed price contract will be awarded as a result of this synopsis/solicitation."

The notice text

The text below is SAM.gov's own, unedited.

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number 1240B27Q0025 is issued as a Request for Quotation (RFQ) for Research Triangle Park Forestry Sciences Laboratory HVAC Repair This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 The small business size standard is $19 M This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. The primary HVAC system (ACCU-1/VRV 2-7) for the Forest Science and Assessment Center (FSAC) is a Mitsubishi VRF system (BHM06227, Model PURY-P120TLMU-A, Serial 79W00897, 10 tons, R-410A) with 6 interior units. The system does not maintain condition set points and an initial evaluation during a preventative maintenance service call diagnosed with a potentially significant refrigerant leak. The Forestry Science Laboratory (FSL) building’s Fan Coil Units (FCUs) are redundant in the current HVAC system. The outside air vents are no longer needed and are introducing unconditioned air into the building. During cold weather, this can lead to the coils potentially freezing and have led to the freeze-stats tripping, resulting in nuisance shutdowns.

Attachments

The files SAM.gov lists with this notice. Open them on SAM.gov, or ask Claude to read them.

What SAM.gov has posted, oldest first

NoticePostedResponse due
Combined Synopsis/SolicitationNovember 19, 2026December 1, 2026, 5:00 PM ET

Open solicitations like this one

Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.