Every answer cites notice numbers you can check on SAM.gov. See a real answer

Notices · Sources Sought

Repair Naval Reserve Training Facility B3370

Open. Responses are due in 856 days, on April 1, 2029, 12:00 PM ET.

Solicitation numberDKGV-1137999
Notice typeSources Sought
AgencyDEPT OF DEFENSE, DEPT OF THE AIR FORCE, FA4418 628 CONS PK
Set-asideSmall Business Set Aside - Total (SBA)
NAICS236220 Commercial and Institutional Building Construction
SBA size standard: $45M average annual receipts
Product or service codeZ2AA Repair or Alteration of Office Buildings
Place of performanceCharleston AFB, SC 29404, USA
PostedMarch 17, 2026
Response dueApril 1, 2029, 12:00 PM ET

Who holds the work now

Largest current award in NAICS 236220 at the Department of the Air Force, by dollars obligated: J.E. DUNN CONSTRUCTION COMPANY, current end date August 4, 2028. It may not be the contract this notice replaces.

Source: USAspending.gov, as of November 3, 2026.

Ask Claude about this notice

Add BidOpps AI to Claude, then type this:

Using BidOpps AI, read DKGV-1137999 in full and tell me what stage it's at.

Add to Claude

Your first 10 searches are free. No card.

The notice text

The text below is SAM.gov's own, unedited.

The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Naval Reserve Training Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 – Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00

What SAM.gov has posted, oldest first

NoticePostedResponse due
Sources SoughtMarch 16, 2026April 1, 2029, 12:00 PM ET
Sources SoughtMarch 17, 2026April 1, 2029, 12:00 PM ET

Open solicitations like this one

Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.