Notices · Solicitation
REPLACE RADIANT HEATING SYSTEM AND EXHAUST FAN, BLDG. 362 DAM NECK ANNEX, VIRGINIA BEACH, VA
Open. Responses are due in 18 days, on December 15, 2026, 2:00 PM ET.
| Solicitation number | N4008527R0037 |
|---|---|
| Notice type | Solicitation |
| Agency | DEPT OF DEFENSE, DEPT OF THE NAVY, NAVFACSYSCOM MID-ATLANTIC |
| Set-aside | Small Business Set Aside - Total (SBA) |
| NAICS | 236220 Commercial and Institutional Building Construction SBA size standard: $45M average annual receipts |
| Product or service code | Z2AZ Repair or Alteration of Other Administrative Facilities and Service Buildings |
| Place of performance | 23460 |
| Posted | November 17, 2026 |
| Response due | December 15, 2026, 2:00 PM ET |
Who holds the work now
Largest current award in NAICS 236220 at the Department of the Navy, by dollars obligated: BLACK CONSTRUCTION-TUTOR PERINI JV, current end date June 24, 2031. It may not be the contract this notice replaces.
Source: USAspending.gov, as of November 3, 2026.
Ask Claude about this notice
Add BidOpps AI to Claude, then type this:
Using BidOpps AI, read N4008527R0037 in full and tell me what stage it's at.
Your first 10 searches are free. No card.
From the attachments
Pulled by AI from 7 of 10 files with text. Check the file before relying on a fact. A point with no row here was not found, which does not mean it doesn't apply. Each quote is the file's own words.
| Evaluation | lowest price N4008527R0037 GENERAL REQUIREMENTS .pdf, page 4: "For this task order, to make a determination of best value, the Government shall evaluate each offeror on price only and the basis for award will be low price." |
|---|---|
| Evaluation factors | PRICE N4008527R0037 GENERAL REQUIREMENTS .pdf, page 6: "The Government will evaluate price based on the total price." |
| Questions due | November 27, 2026, 2:00 PM EST N4008527R0037 GENERAL REQUIREMENTS .pdf, page 4: "PPIs must be submitted in writing on the attached Pre-Proposal Inquiry Form (ATTACHMENT J) to Maria Bayse at maria.bayse.civ@us.navy.mil no later than 27 November 2026 2:00 PM EST." |
| Site visit | see the quote N4008527R0037 AMENDMENT 0001.pdf, page 1: "The purpose of this amendment is to issue Site Visit Log, extend PPI submission due date, and extend proposal submission due date." |
| Site visit | November 18, 2026 N4008527R0037 GENERAL REQUIREMENTS .pdf, page 4: "Date and Time: Wednesday, 18 November 2026, 9:00 am EST" |
| Clearance | clearance to the SOCOM compound from the Activity's Security Officer ATTACHMENT A_ SCOPE OF WORK DN 362-REPLACE RADIANT HEATING…, page 9: "All Contractor personnel associated with this contract must obtain clearance to the SOCOM compound from the Activity's Security Officer in order to perform work in Building 362." |
| Bonding | bid guarantee (Standard Form 24) in a penal sum equal to at least 20 percent of the offer price or… N4008527R0037 GENERAL REQUIREMENTS .pdf, page 4: "each offeror shall submit with its offer a guarantee bond (Standard Form 24) in a penal sum equal to at least 20 percent of the offer price or $3,000,000, whichever is less." |
| Bonding | performance and payment bonds N4008527R0037 GENERAL REQUIREMENTS .pdf, page 4: "Performance and Payment Bonds are required from the contract task order awardee fifteen (15) calendar days after date of award." |
| Past performance | Superintendent: minimum 5 years of experience as a Superintendent on previous projects of similar s… ATTACHMENT A_ SCOPE OF WORK DN 362-REPLACE RADIANT HEATING…, page 11: "The Superintendent must have a minimum of 5 years of experience as a Superintendent on previous projects of similar size and complexity." |
| Past performance | QC Manager: minimum 5 years combined experience as a Project Superintendent, QC Manager, inspector,… ATTACHMENT A_ SCOPE OF WORK DN 362-REPLACE RADIANT HEATING…, page 25: "The QC Manager must have a minimum 5 years of combined experience as a Project Superintendent, QC Manager, inspector, Project Manager, Project Engineer or Construction Manager on previous projects of similar size and complexity." |
| Past performance | Installers must be BICSI-registered or have a minimum of 3 years' experience; two completed cabling… ATTACHMENT A_ SCOPE OF WORK DN 362-REPLACE RADIANT HEATING…, page 77: "Include names and locations of two projects successfully completed using optical fiber and/or copper communications cabling systems." |
The notice text
The text below is SAM.gov's own, unedited.
Attachments
The files SAM.gov lists with this notice. Open them on SAM.gov, or ask Claude to read them.
- ATTACHMENT A_ SCOPE OF WORK DN 362-REPLACE RADIANT HEATING SYSTEM.pdf
- ATTACHMENT B_WAGE DETERMINATION.pdf
- B362 Site Visit Log.pdf
- N4008527R0037 AMENDMENT 0001.pdf
- ATTACHMENT C_BASE ACCESS INSTRUCTION.pdf
- ATTACHMENT D_ SECNAV 5512.pdf
- N4008527R0037 GENERAL REQUIREMENTS .pdf
- ATTACHMENT H_PIEE Vendor Access Instructions.pdf
- ATTACHMENT F_BLANK DEVGRU SPREADSHEET.xlsx
- ATTACHMENT E_BLANK SPONSOR VERIFICATION SHEET.xlsx
- ATTACHMENT J_PPI_Spreadsheet.xlsx
What SAM.gov has posted, oldest first
| Notice | Posted | Response due |
|---|---|---|
| Solicitation | November 3, 2026 | December 7, 2026, 2:00 PM ET |
| Solicitation | November 3, 2026 | December 7, 2026, 2:00 PM ET |
| Solicitation | November 17, 2026 | December 15, 2026, 2:00 PM ET |
| Solicitation | November 17, 2026 | December 15, 2026, 2:00 PM ET |
Open solicitations like this one
Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.