Every answer cites notice numbers you can check on SAM.gov. See a real answer

Notices · Combined Synopsis/Solicitation

Plate Reader

Closed. Responses were due August 6, 2026, 1:00 PM ET.

Solicitation numberW911S226U3818
Notice typeCombined Synopsis/Solicitation
AgencyDEPT OF DEFENSE, DEPT OF THE ARMY, W6QM MICC-FT DRUM
Set-asideSmall Business Set Aside - Total (SBA)
NAICS334516 Analytical Laboratory Instrument Manufacturing
SBA size standard: 1,000 employees
Product or service code6630 Chemical Analysis Instruments
Place of performance10996
PostedJuly 27, 2026
Response dueAugust 6, 2026, 1:00 PM ET

Who holds the work now

Largest current award in NAICS 334516 at the Department of the Army, by dollars obligated: PENDAR TECHNOLOGIES LLC, current end date June 29, 2027. It may not be the contract this notice replaces.

Source: USAspending.gov, as of November 3, 2026.

Ask Claude about this notice

Add BidOpps AI to Claude, then type this:

Using BidOpps AI, read W911S226U3818 in full and tell me what stage it's at.

Add to Claude

Your first 10 searches are free. No card.

The notice text

The text below is SAM.gov's own, unedited.

Amended to include set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 ?C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.

What SAM.gov has posted, oldest first

NoticePostedResponse due
Combined Synopsis/SolicitationJuly 23, 2026August 6, 2026, 1:00 PM ET
Combined Synopsis/SolicitationJuly 27, 2026August 6, 2026, 1:00 PM ET

Open solicitations like this one

Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.