Every answer cites notice numbers you can check on SAM.gov. See a real answer

Notices · Combined Synopsis/Solicitation

iWorx

Closed. Responses were due November 26, 2026, 11:00 AM ET.

Solicitation numberW911S227U0166
Notice typeCombined Synopsis/Solicitation
AgencyDEPT OF DEFENSE, DEPT OF THE ARMY, W6QM MICC-FT DRUM
Set-asideSmall Business Set Aside - Total (SBA)
NAICS334516 Analytical Laboratory Instrument Manufacturing
SBA size standard: 1,000 employees
Product or service code6630 Chemical Analysis Instruments
Place of performance10996
PostedNovember 15, 2026
Response dueNovember 26, 2026, 11:00 AM ET

Who holds the work now

Largest current award in NAICS 334516 at the Department of the Army, by dollars obligated: PENDAR TECHNOLOGIES LLC, current end date June 29, 2027. It may not be the contract this notice replaces.

Source: USAspending.gov, as of November 3, 2026.

Ask Claude about this notice

Add BidOpps AI to Claude, then type this:

Using BidOpps AI, read W911S227U0166 in full and tell me what stage it's at.

Add to Claude

Your first 10 searches are free. No card.

The notice text

The text below is SAM.gov's own, unedited.

Amended to add set aside code. iWorx System Required System Specifications, Minimum 18-channel data recorder with the ability to expand to additional channels. Competing systems typically provide only 2-4 channels. Ability to gang multiple recorders together for expanded data acquisition. Includes 2 channels of wireless ECG/EMG and 3-axis accelerometer capability, with expansion to 16 wired channels. Competing products generally provide only 1-2 channels. Includes an ECG simulator. Integrated Pulse Oximetry, spirometry, grip force, and intensity sensors designed for enhanced measurement accuracy. Pre-calibrated temperature, force, spirometry, and blood pressure sensors, allowing immediate use with minimal setup requirements. Two built-in low-voltage input channels (+/-15V). Built-in isolated constant current high-voltage stimulator. Must be iWire compatible, allowing future expansion and integration of additional sensors and instrumentation. Expandable to a minimum of 34 total channels. Integrated barometric pressure sensor to improve spirometry accuracy without requiring separate external hardware. Minimum 16 digital I/O channels. Minimum 1 audio output channel. Portable design capable of operation through a USB-C power connection. Includes lifetime free LabScribe software updates and an open site license. Includes unlimited online training at no additional cost.

What SAM.gov has posted, oldest first

NoticePostedResponse due
Combined Synopsis/SolicitationNovember 10, 2026November 26, 2026, 11:00 AM ET
Combined Synopsis/SolicitationNovember 15, 2026November 26, 2026, 11:00 AM ET

Open solicitations like this one