Notices · Special Notice
H--FLEX – MODULAR SF6 ANALYZER
Closed. Responses were due November 13, 2026, 1:30 PM ET.
| Solicitation number | 89503427QWA001337 |
|---|---|
| Notice type | Special Notice |
| Agency | ENERGY, DEPARTMENT OF, WESTERN-UPPER GREAT PLAINS REGION |
| Set-aside | Not listed |
| NAICS | 334513 Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables SBA size standard: 750 employees |
| Product or service code | H299 Equipment and Materials Testing: Miscellaneous |
| Place of performance | Not listed |
| Posted | November 9, 2026 |
| Response due | November 13, 2026, 1:30 PM ET |
Who holds the work now
USAspending shows no current award in NAICS 334513 at the Department of Energy, and this notice names no contract we hold.
Source: USAspending.gov, as of November 3, 2026.
Ask Claude about this notice
Add BidOpps AI to Claude, then type this:
Using BidOpps AI, read 89503427QWA001337 in full and tell me what stage it's at.
Your first 10 searches are free. No card.
The notice text
The text below is SAM.gov's own, unedited.
Issued on November 10, 2026 The Western Area Power Administration, Upper Great Plains (UGP), intends to acquire, on a sole-source basis, a GasQuip Flex Modular SF6 Analyzer for the South Dakota Maintenance Office to support its missions. The resulting procurement will be conducted in accordance with FAR Part 12. WAPA requires continuous, uninterrupted testing of high-voltage sulfur hexafluoride (SF?) and emerging eco-efficient dielectric gas mixtures (such as N?/SF? blends) to safeguard grid reliability and regulatory compliance; market research indicates only the GasQuip FLEX satisfies all mission requirements. Unlike conventional analyzers with fixed sensor manifolds that require a full-chassis return to the OEM for mandatory annual calibration—creating 2- to 3-month operational testing blind spots or redundant backup acquisitions—the GasQuip FLEX uses proprietary, pre-calibrated modular sensors that can be field-swapped in under 60 seconds without taking the primary diagnostic unit out of service. Additionally, its modular multi-bay chassis accommodates future eco-gas modules within existing hardware to eliminate future capital obsolescence costs, while its integrated active hose evacuation function completely removes toxic decomposition byproducts (e.g., SO?) and ambient moisture between test points to eliminate cross-contamination and prevent false hazard alerts without wasting insulating gas. THIS IS NOT A REQUEST FOR COMPETITIVE QUOTES. Capability statements must be received within three calendar days of this notice and should include documentation demonstrating the ability to meet the Government’s requirements. The Government reserves the right, in its sole discretion, to determine whether to compete this requirement based on the responses received. Questions concerning this notice may be directed to the Contract Officer, Irma Suryaty, at suryaty@wapa.gov.
What SAM.gov has posted, oldest first
| Notice | Posted | Response due |
|---|---|---|
| Special Notice | November 9, 2026 | November 13, 2026, 1:30 PM ET |
Open solicitations like this one
Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.