Notices · Presolicitation
C1DZ--460-26-001 Renovate Exterior of Main Hospital
Closed. Responses were due July 13, 2026, 3:00 PM ET.
| Solicitation number | 36C24426R0113 |
|---|---|
| Notice type | Presolicitation |
| Agency | VETERANS AFFAIRS, DEPARTMENT OF, 244-NETWORK CONTRACT OFFICE 4 (36C244) |
| Set-aside | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC) |
| NAICS | 541330 Engineering Services SBA size standard: $25.5M average annual receipts; exception for Military and Aerospace Equipment and Military Weapons: $47M average annual receipts; exception for Contracts and Subcontracts for Engineering Services Awarded Under the National Energy Policy Act of 1992: $47M average annual receipts; exception for Marine Engineering and Naval Architecture: $47M average annual receipts |
| Product or service code | C1DZ Architect and Engineering- Construction: Other Hospital Buildings |
| Place of performance | Wilmington, DE 19805, USA |
| Posted | November 15, 2026 |
| Response due | July 13, 2026, 3:00 PM ET |
Who holds the work now
Largest current award in NAICS 541330 at the Department of Veterans Affairs, by dollars obligated: AMERESCO INC, current end date October 1, 2038. It may not be the contract this notice replaces.
Source: USAspending.gov, as of November 3, 2026.
Ask Claude about this notice
Add BidOpps AI to Claude, then type this:
Using BidOpps AI, read 36C24426R0113 in full and tell me what stage it's at.
Your first 10 searches are free. No card.
The notice text
The text below is SAM.gov's own, unedited.
Page 13 of 13 Additional clarifying details added though this revision posting. Changes in this revision can be seen highlighted in green. Yellow highlighted text reflects the previous corrections made from the original posting. An Extension to the due date has been made accordingly. Further extension requests are not feasible to the timeframe for this intended FY26 contract award. All other details remain as originally posted. ACQUISITION INFORMATION: The Wilmington Department of Veterans Affairs Medical Center located at 1601 Kirkwood Highway, Wilmington DE, 19805 is seeking professional Architect and Engineering (A&E) services for Project No. 460-26-001, Renovate Exterior of Main Hospital Design. This announcement is being issued in accordance with the Selection of Architects and Engineering firms (Public Law 92-582) and implemented in the Federal Acquisitions Regulations (FAR) Part 36. Architectural and Engineering (A&E) firms permitted by law to practice the professions of architecture or engineering are requested to send one copy of an SF 330 (7/2021 Edition) via email with qualified and eligible firms classified as 100% SERVICE DISABLED VETERAN OWNED SMALL BUSINESS CONCERNS. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. This is not a Request for Proposal and an award will not be made with this announcement. This announcement is a request for SF 330s from qualified firms that meet the professional and set aside requirements listed in this announcement. Contract Award Procedure: Interested A&E Firms should e-mail a PDF SF330 document to Hanna Karmazyn at Hanna.Karmazyn@va.gov by 3:00 PM, EST, July 13, 2026. A&E firms shall be registered at www.sam.gov and www.vetbiz.gov. If available, please include your firm's VetBiz.gov SDVOSB status verification. Failure of a proposed SDVOSB A&E firm to be certified by the CVE at the time of the SF330 is submitted shall result in elimination from further consideration for award. Following an evaluation of the qualifications and performance data submitted, three or more firms considered to be the most highly qualified firms to provide the type of services require may be chosen for interviews. After interviews, the most highly qualified firm will be issued the solicitation and requested to submit a proposal. The Government will not pay, nor reimburse, any costs associated with responding to this announcement. The Government is under no obligation to award a contract as a result of this announcement. A&E Firms will be selected based on demonstrated competence and qualifications for the required work. NAICS 541330 and size standard $25.5M apply. NAICS 541330 covers engineering design, development and utilization of structures and systems and remains the appropriate code for this procurement. The award of a Firm Fixed-Price contract is contemplated and is subject to the availability of FY26 funding. The construction magnitude is between $2,000,000.00 and $5,000,000.00. A/E Evaluation Factors I. Experience and Past Performance a. Healthcare Planning Experience Provide a brief overview of the firm s history and experience in healthcare planning. Include at least 5 relevant projects. Add emphasis on exterior renovations, ADA accessibility upgrades, and work performed in active medical facilities requiring phasing. b. Federal Contract Experience Demonstrate experience with federal contracts, especially VA projects. Include familiarity with VA TIL, and maintaining facility operations during construction. II. Design Team Proposed for This Project a. Qualifications of Key Personnel Provide resumes (max 10) showing experience in healthcare and federal projects. Include experience with ADA compliance, site design (grading/drainage), and life safety. b. Subconsultants Provide qualifications of subcontractors, especially for civil/site work, industrial hygiene, and fire/life safety. c. Design Approach Describe approach to ADA, NFPA Life Safety Code, infection control, and exterior material selection. III. Technical Approach Describe approach to incorporating ADA, NFPA Life Safety Code, energy conservation, and site improvements. Include understanding of renovating an active hospital entrance, maintaining safe access, and minimizing disruption through phasing. IV. Proposed Management Plan a. Project Management Approach Describe approach to schedule, budget, risk management, and communication. b. Work Plan and Deliverables Provide plan to meet design milestones (25%, 75%, 100%, final) and ability to meet submission dates. c. Compliance Standards Demonstrate knowledge of NFPA, NEC, OSHA, and other applicable codes. d. VA Specific Standards Demonstrate familiarity with VA requirements, TIL, and PDT process. V. Location and Knowledge of Local Area a. Firm Location Provide office locations and ability to support site visits and response times. b. Local Knowledge Demonstrate knowledge of Wilmington VAMC, local construction conditions, and factors impacting cost and schedule Wilmington, DE VA Medical Center Wilmington, DE 19805 A/E SCOPE OF WORK For Renovate The Exterior Of Main Hospital Project No. 460-26-001 Bid Documents/Final Report Ready By: 180 days after NTP -- Services -- Provide: Professional A/E and healthcare planning services to include but not limited to: Site investigation architectural, structural, mechanical, electrical, and environmental services. Contract drawings and specifications for construction. 3rd Party Cost Estimates Construction period services - review of submissions, provide recommendations regarding contractor change proposals, visit site per VA's request and add to drawings as-built conditions from contractor's record drawings; A/E will respond on site within a two-hour period when requested. Infection Control Risk Assessment Meet all of the requirements as outlined in VA Program Guide PG-18-15 (Volume C), A/E Submission Instructions for Minor and NRM Construction Program. Reference at https://www.cfm.va.gov/cfm/til/index.asp -- Project Scope -- GENERAL: This project consists of the renovation of the main exterior entrance of Building 1 at the Wilmington VA Medical Center. Work includes demolition, redesign, and reconstruction of entrance features and installation of a new ADA-compliant handicap ramp. SPECIFICS: Evaluate and redesign entrance plaza, sidewalks, and approach paths and associated roadways Design ADA-compliant ramp including slopes, handrails, landings Improve drainage, grading Upgrade exterior finishes, railings, entry features and any architectural façade as deemed necessary Maintain facility operations during construction Identify and correct life safety deficiencies and provide phasing plan if necessary All designs shall be accomplished in accordance with VA guidelines and specifications, which are available on the Internet at https://www.cfm.va.gov/cfm/til/index.asp and https://wbdg.org/ffc/federal-facility-criteria. The A/E will follow VA design guides and provide revised and improved specifications based on the VA standard specifications. . Other Specifics: AutoCAD files of existing design will be provided for use. Phase all work in coordination with Hospital staff to minimize down-time to areas affected by the project. Construction Waste Management, s to be included. Design to maintain all infection control/ dust prevention measures. List all Permits necessary to complete the project. Consolidate all necessary submittals by specification section on an excel spreadsheet. Checklist to be utilized to track/ monitor submittal process. All designs shall be accomplished in accordance with VA guidelines and specifications, which are available on the Internet at https://www.cfm.va.gov/cfm/til/index.aspThe A/E will follow VA design guides and provide revised and improved specifications based on the VA standard specifications. -- Site Investigations -- EXPECTATION: A/E will make site visits as necessary to survey existing conditions. Make site visits as required to determine existing as-built conditions affecting this project. Provide any structural, architectural, electrical, and mechanical investigative work including all interior and exterior, of both existing and designed systems necessary to ensure the accuracy of the design. Prepare any measured drawings of existing systems of facility required to ensure the accuracy of the design. Provide a CIH to evaluate the impacted building areas for asbestos. Wilmington VA has an asbestos survey which will need to be verified. Provide a CIH to evaluate the impacted building areas for lead based paint. Exterior window frames have not been tested for lead based paint, but exterior doors have and several did test positive. NOTE: Information including drawings and other documentation provided to the A/E is used as reference only. All additional references and specifications are available in VHA s Technical Information Library at address http://www.cfm.va.gov. AutoCAD background drawings will be provided by the VA upon request. The A/E shall field verify all dimensions. A/E shall field verify every aspect that relates to the project. Coordinate site visits with the Project Engineer. -- Environmental/Occupational Safety and Health (EOSH) -- EXPECTATION: All projects and project designs shall contain language that addresses all applicable EOSH requirements. Regulatory Compliance EOSH requirements for work performed at the above location can be found in: Volume 29 of the Code of Federal Regulations, Part 1910 Occupational Safety for General Industry Volume 29 of the Code of Federal Regulations, Part 1926 Occupational Safety for The Construction Industry Volume 40 of the Code of Federal Regulations Protection of The Environment Volume 49 of the Code of Federal Regulations, Part 397 Transportation of Hazardous Materials Title 7 of the Delaware Code Conservation Title 16 of the Delaware Code Health and Safety Specifications The VA Master Construction Specifications contain work procedures and material requirements designed to meet regulatory compliance requirements. Whenever possible, the Master Construction Specifications must be used as the basis for project designs. A complete list of these specifications can be viewed at the following website: https://www.cfm.va.gov/cfm/til/index.aspSpecifications which address EOSH requirements include, but are not limited to -- Design Review Schedule -- EXPECTATION: Submit review packages so they are received on the noted day. SUBMISSIONS: Submit review packages so they are received on the noted day (calendar days after NTP) or earlier: Notice to Proceed Day 0 (0 days) Initial Meeting with Stakeholders Day 14 (14 days) Design Development Document Submission (25%) Day 44 (30 days) PDT Review Meeting (25%) Day 58 (14 days) Design Development Document Submission (75%) Day 93 (35 days) PDT Review Meeting (75%) Day 107 (14 days) Design Development Document Submission (100%) Day 152 (45 days) PDT Review Meeting (100%) Day 166 (14 days) Contract Documents Submission (Final) Day 180 (14 days) Note: The issue of the NTP will be the first PDT Meeting. A/E will be required to attend and take minutes of each Project Design Team (PDT) Meeting. Minutes will be submitted electronically to the Project Manager and Contracting Officer within three calendar days of each meeting. -- Specification Requirements -- -- Design Requirements/Submissions -- EXPECTATION: Submit complete review package in accordance with the following requirements and guidelines outlined in http://www.cfm.va.gov. Please pay specific attention to the schematic, design and construction submission requirements. As appropriate depending upon the complexity of the design, the A/E may elect to delete individual submissions where they are not required (i.e. Do not address Site Development, Landscaping for interior renovation projects) DELIVER: All design packages directly to the Project Engineer on the established dates to
The rest of the text is on SAM.gov.
What SAM.gov has posted, oldest first
| Notice | Posted | Response due |
|---|---|---|
| Presolicitation | May 21, 2026 | June 22, 2026, 3:00 PM ET |
| Presolicitation | June 17, 2026 | July 6, 2026, 3:00 PM ET |
| Presolicitation | June 25, 2026 | July 13, 2026, 3:00 PM ET |
| Special Notice | November 15, 2026 | |
| Presolicitation | November 15, 2026 | July 13, 2026, 3:00 PM ET |
Open solicitations like this one
Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.