Every answer cites notice numbers you can check on SAM.gov. See a real answer

Notices · Sources Sought

J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC

Open. Responses are due in 18 days, on December 15, 2026, 10:00 AM ET.

Solicitation number36C24527Q0083
Notice typeSources Sought
AgencyVETERANS AFFAIRS, DEPARTMENT OF, 245-NETWORK CONTRACT OFFICE 5 (36C245)
Set-asideNot listed
NAICS561621 Security Systems Services (except Locksmiths)
SBA size standard: $25M average annual receipts
Product or service codeJ063 Maint/Repair/Rebuild of Equipment- Alarm, Signal, and Security Detection Systems
Place of performanceWashington, DC 20422, USA
PostedNovember 22, 2026
Response dueDecember 15, 2026, 10:00 AM ET

Who holds the work now

Largest current award in NAICS 561621 at the Department of Veterans Affairs, by dollars obligated: NATIONAL PROJECT MANAGEMENT LLC, current end date October 5, 2027. It may not be the contract this notice replaces.

Source: USAspending.gov, as of November 3, 2026.

Ask Claude about this notice

Add BidOpps AI to Claude, then type this:

Using BidOpps AI, read 36C24527Q0083 in full and tell me what stage it's at.

Add to Claude

Your first 10 searches are free. No card.

The notice text

The text below is SAM.gov's own, unedited.

SUMMARY The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services. The Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required. NCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services. Anticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063 Please submit your capabilities statement and provide responses to all questions listed below. SOURCES SOUGHT NOTICE: 36C24527Q0083 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability and expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Respond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET. Send all responses to Billie.Pratt@va.gov Subject line on email: 36C24527Q0083 Sources Sought Notice | Company Name STATEMENT OF WORK Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement Department of Veterans Affairs | Washington DC VA Medical Center 50 Irving Street NW, Washington, DC 20422 Draft dated October 27, 2026 1. BACKGROUND The Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access. VA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods. 2. SCOPE OF WORK The Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are "or equal." 3. LOCATIONS AND EXISTING CONDITIONS Item Location / Type Quantity Notes 1 Barrier-arm gates (standard duty, 12 14 ft arm) 17 Parking lots and service drives; includes separated Fisher House locations. 2 Barrier-arm gate (long arm, approx. 20 ft) 1 Heavy-duty operator; status reporting appropriate to hardware. 3 Slide gate Utility Building 8 1 Reuse existing gate panel; convert from top track to bottom steel cantilever track. 4 Lots 3B and 4B Gates as installed (verify) Relocatable (forklift-movable) foundations and flexible wiring for planned two-way operation. Total gate locations 19 Contractor shall verify all locations and conditions during the mandatory site visit. Existing 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope. 4. TECHNICAL REQUIREMENTS GATE SYSTEM 4.1 Removal and Disposal Remove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads. Removal and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan. 4.2 Barrier Gate Operators Commercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable. Integral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service. LED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system. Above-ground radar ("virtual loop") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations. One (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property. 4.3 Slide Gate Utility Building 8 Convert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required. Furnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable. 4.4 Relocatable Foundations Lots 3B and 4B Provide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey. 4.5 Remote Monitoring and Control Provide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release. The dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available. All life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices. Communications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO. 4.6 Event Cameras Nineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events. Cloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only. 4.7 Cloud Platform, Information Security and Privacy The hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled. All data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract. User access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication. 4.8 Commissioning, Testing and Training Submit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police. Provide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover. 4.9 Warranty Minimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA. 5. MANDATORY SUBCONTRACT JOHNSON CONTROLS, INC. (PIV BADGE READERS) The VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply: Subcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty. Readers. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration. Controllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to

The rest of the text is on SAM.gov.

Attachments

SAM.gov lists 1 file with this notice. Open it on SAM.gov, or ask Claude to read it.

What SAM.gov has posted, oldest first

NoticePostedResponse due
Sources SoughtNovember 22, 2026December 15, 2026, 10:00 AM ET

Open solicitations like this one

Source: this notice on SAM.gov, from SAM.gov's public extract of contract notices, last loaded November 27, 2026.